Skip to main content
Back to Products
Image coming soon
Pressure Regulating Valves (70000 Series)
PSM Series70000

Pressure Regulating Valve (70000 Series) Type F

Coming soon

Catalogue Cv curve & tableEngineering estimate

Cv vs opening percentage — PSM reference catalogue data

Rated Cv 1.5NPS 0.25"Characteristic Equal %Cv ratio at 50% 0.242Rangeability 40Confidence very lowBack-test error ±62%
1120255075100% opening
Opening %Cv% of rated
1002%
200.16%
300.19%
400.216%
500.424%
600.637%
700.856%
801.175%
901.489%
1001.5100%

This table is not manufacturer measured data: Cv comes from the scaling law fitted to the measured series (back-test error ±62%, confidence very low). Confirm with PSM engineering before ordering.

Get Consultation